ASTM Thermometers 25 C&F to 44 C&F
All of the ASTM thermometers listed in this catalog are produced by manufacturers of outstanding quality. Strict manufacturing procedures and quality controls ensure the fabrication of thermometers which are fully in compliance with the dimensional and accuracy requirements of ASTM Specification E-1.
All thermometers are available with or without a NIST traceable, ISO/IEC 17025 and ANSI/NCSL Z540-1 accredited report of calibration.
ASTM Thermometers with NIST traceable, ISO/IEC 17025 and ANSI/NCSL Z540-1 accredited report of calibration
ASTM No. | Cat No. | Application | Range | Div | Length | Immersion | ASTM specified test points |
---|---|---|---|---|---|---|---|
25C | 10025C-C | Viscosity Engler | 95 to 105 °C | 0.2° | 212mm | 90mm | 95, 100 °C |
26C | 10026C-C | Stab Test Sol Nit Cell | 130 to 140 °C | 0.1° | 463mm | total | 130, 135, 140 °C |
27C | 10027C-C | Turpentine Dist. | 147 to 182 C | 0.5° | 301mm | 76mm | 155, 165, 175 °C |
28C | 10028C-C | Kinematic viscosity @ 37.8 °C | 36.6 to 39.4 °C | 0.05° | 305mm | total | 0, 37.8, 39 °C |
28F | 10028F-C | Kinematic viscosity @ 100 °F | 97.5 to 102.5 °F | 0.1° | 305mm | total | 32, 100, 102 °F |
29C | 10029C-C | Kinematic viscosity @ 54.4 °C | 52.6 to 55.4 °C | 0.05° | 305mm | total | 0, 54.4C, 55 °C |
29F | 10029F-C | Kinematic viscosity @ 130 °F | 127.5 to 132.5 °F | 0.1° | 305mm | total | 32, 130, 132 °F |
30F | 10030F-C | Kinematic viscosity @ 210 °F | 207.5 to 212.5 °F | 0.1° | 305mm | total | 32, 210, 212 °F |
31F | 10031F-C | Reid Vapor | -30 to 120 °F | 1° | 305mm | total | -20, 32, 100 °F |
33C | 10033C-C | Aniline Point | -38 to 42 °C | 0.2° | 420mm | 50mm | -35, -20, 0, 20, 40 °C |
33F | 10033F-C | Aniline Point | -36.5 to 107.5 °F | 0.5° | 420mm | 50mm | -31, -4, 32, 68, 104 °F |
34C | 10034C-C | Aniline Point | 25 to 105 °C | 0.2° | 420mm | 50mm | 25, 45, 65, 85, 100 °C |
34F | 10034F-C | Aniline Point | 77 to 221 °F | 0.5° | 420mm | 50mm | 77, 113, 149, 185, 212 °F |
35C | 10035C-C | Aniline Point | 90 to 170 °C | 0.2° | 420mm | 50mm | 100, 120, 140, 160, 170 °C |
35F | 10035F-C | Aniline Point | 194 to 338 °F | 0.5° | 420mm | 50mm | 212, 250, 285, 320, 338 °F |
36C | 10036C-C | Titer Test | -2 to 68 °C | 0.2° | 405mm | 45mm | 0, 15, 30, 45, 65 °C |
37C | 10037C-C | Solvents Distillation | -2 to 52 °C | 0.2° | 395mm | 100mm | 0, 15, 30, 50 °C |
38C | 10038C-C | Solvents Distillation | 24 to 78 °C | 0.2° | 395mm | 100mm | 25, 40, 55, 75 °C |
39C | 10039C-C | Solvents Distillation | 48 to 102 °C | 0.2° | 395mm | 100mm | 50, 65, 80, 100 °C |
40C | 10040C-C | Solvents Distillation | 72 to 126 °C | 0.2° | 395mm | 100mm | 75, 90, 105, 125 °C |
41C | 10041C-C | Solvents Distillation | 98 to 152 °C | 0.2° | 395mm | 100mm | 100, 115, 130, 150 °C |
42C | 10042C-C | Solvents Distillation | 95 to 255 °C | 0.5° | 395mm | 100mm | 100, 150, 200, 250 °C |
43C | 10043C-C | Kinematic Viscosity | -51.6 to -34 °C | 0.1° | 417mm | total | -50, -45, -40, -35, 0 °C |
43F | 10043F-C | Kinematic Viscosity | -61 to -29 °F | 0.2° | 417mm | total | -60, -50, -40, -30, 32 °F |
44C | 10044C-C | Kinematic viscosity @ 20 °C | 18.5 to 21.5 °C | 0.05° | 305mm | total | 0, 20, 21 °C |
44F | 10044F-C | Kinematic viscosity @ 68 °F | 66.5 to 71.5 °F | 0.1° | 305mm | total | 32, 68, 70 °F |
ASTM Thermometers without calibration
ASTM No. | Cat No. | Application | Range | Div | Length | Immersion |
---|---|---|---|---|---|---|
25C | 10025C | Viscosity Engler | 95 to 105 °C | 0.2° | 212mm | 90mm |
26C | 10026C | Stab Test Sol Nit Cell | 130 to 140 °C | 0.1° | 463mm | total |
27C | 10027C | Turpentine Dist. | 147 to 182 °C | 0.5° | 301mm | 76mm |
28C | 10028C | Kinematic viscosity @ 37.8 °C | 36.6 to 39.4 °C | 0.05° | 305mm | total |
28F | 10028F | Kinematic viscosity @ 100 °F | 97.5 to 102.5 °F | 0.1° | 305mm | total |
29C | 10029C | Kinematic viscosity @ 54.4 °C | 52.6 to 55.4 °C | 0.05° | 305mm | total |
29F | 10029F | Kinematic viscosity @ 130 °F | 127.5 to 132.5 °F | 0.1° | 305mm | total |
30F | 10030F | Kinematic viscosity @ 210 °F | 207.5 to 212.5 °F | 0.1° | 305mm | total |
31F | 10031F | Reid Vapor | -30 to 120 °F | 1° | 305mm | total |
33C | 10033C | Aniline Point | -38 to 42 °C | 0.2° | 420mm | 50mm |
33F | 10033F | Aniline Point | -36.5 to 107.5 °F | 0.5° | 420mm | 50mm |
34C | 10034C | Aniline Point | 25 to 105 °C | 0.2° | 420mm | 50mm |
34F | 10034F | Aniline Point | 77 to 221 °F | 0.5° | 420mm | 50mm |
35C | 10035C | Aniline Point | 90 to 170 °C | 0.2° | 420mm | 50mm |
35F | 10035F | Aniline Point | 194 to 338 °F | 0.5° | 420mm | 50mm |
36C | 10036C | Titer Test | -2 to 68 °C | 0.2° | 405mm | 45mm |
37C | 10037C | Solvents Distillation | -2 to 52 °C | 0.2° | 395mm | 100mm |
38C | 10038C | Solvents Distillation | 24 to 78 °C | 0.2° | 395mm | 100mm |
39C | 10039C | Solvents Distillation | 48 to 102 °C | 0.2° | 395mm | 100mm |
40C | 10040C | Solvents Distillation | 72 to 126 °C | 0.2° | 395mm | 100mm |
41C | 10041C | Solvents Distillation | 98 to 152 °C | 0.2° | 395mm | 100mm |
42C | 10042C | Solvents Distillation | 95 to 255 °C | 0.5° | 395mm | 100mm |
43C | 10043C | Kinematic Viscosity | -51.6 to -34 °C | 0.1° | 417mm | total |
43F | 10043F | Kinematic Viscosity | -61 to -29 °F | 0.2° | 417mm | total |
44C | 10044C | Kinematic viscosity @ 20 °C | 18.5 to 21.5 °C | 0.05° | 305mm | total |
44F | 10044F | Kinematic viscosity @ 68 °F | 66.5 to 71.5 °F | 0.1° | 305mm | total |
WARNING: Mercury is considered a hazardous material that can cause central nervous system, kidney and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury containing products. See the product Material Safety Data Sheet (MSDS) for details. User should be aware that selling mercury and mercury containing products into your state may be prohibited by state law.