ASTM Thermometers 12 C&F to 24 C&F
All of the ASTM thermometers listed in this catalog are produced by manufacturers of outstanding quality. Strict manufacturing procedures and quality controls ensure the fabrication of thermometers which are fully in compliance with the dimensional and accuracy requirements of ASTM Specification E-1.
All thermometers are available with or without a NIST traceable, ISO/IEC 17025 and ANSI/NCSL Z540-1 accredited report of calibration.
ASTM Thermometers with NIST traceable, ISO/IEC 17025 and ANSI/NCSL Z540-1 accredited report of calibration
ASTM No. | Cat No. | Application | Range | Div | Length | Immersion | ASTM specified test points |
---|---|---|---|---|---|---|---|
ASTM No. 12C |
Cat No. 10012C-C |
Application Gravity (Density) |
Range -20 to 102 °C |
Div 0.2° |
Length 420mm |
Immersion total |
ASTM specified test points -20, -10, 0, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 °C |
ASTM No. 12F |
Cat No. 10012F-C |
Application Gravity (Density) |
Range -5 to 215 °F |
Div 0.5° |
Length 420mm |
Immersion total |
ASTM specified test points -5, 15-, 32, 60, 85, 110, 135, 160, 185, 210 °F |
ASTM No. 13C |
Cat No. 10013C-C |
Application Loss on Heat |
Range 155 to 170 °C |
Div 0.5° |
Length 155mm |
Immersion total |
ASTM specified test points 155, 163, 170 °C |
ASTM No. 14C |
Cat No. 10014C-C |
Application Paraffin Wax Melt Point |
Range 38 to 82 °C |
Div 0.1° |
Length 375mm |
Immersion 79mm |
ASTM specified test points 40, 50, 60, 70, 80 °C |
ASTM No. 14F |
Cat No. 10014F-C |
Application Paraffin Wax Melt Point |
Range 100 to 180 °F |
Div 0.2° |
Length 375mm |
Immersion 79mm |
ASTM specified test points 100, 120, 140, 160, 180 °F |
ASTM No. 15C |
Cat No. 10015C-C |
Application Softening Point, Low |
Range -2 to 80 °C |
Div 0.2° |
Length 397mm |
Immersion total |
ASTM specified test points 0, 20, 40, 60, 80 °C |
ASTM No. 15F |
Cat No. 10015F-C |
Application Softening Point, Low |
Range 30 to 180 °F |
Div 0.5° |
Length 397mm |
Immersion total |
ASTM specified test points 32, 70, 100, 140, 180 °F |
ASTM No. 16C |
Cat No. 10016C-C |
Application Softening Point, High |
Range 30 to 200 °C |
Div 0.5° |
Length 397mm |
Immersion total |
ASTM specified test points 30, 60, 90, 120, 150, 180, 200 °C |
ASTM No. 16F |
Cat No. 10016F-C |
Application Softening Point, High |
Range 85 to 392 °F |
Div 1° |
Length 397mm |
Immersion total |
ASTM specified test points 90, 140, 190, 240, 290, 340, 390 °F |
ASTM No. 17C |
Cat No. 10017C-C |
Application Viscosity Saybolt |
Range 19 to 27 °C |
Div 0.1° |
Length 275mm |
Immersion total |
ASTM specified test points 21, 25 °C |
ASTM No. 17F |
Cat No. 10017F-C |
Application Viscosity Saybolt |
Range 66 to 80 °F |
Div 0.2° |
Length 275mm |
Immersion total |
ASTM specified test points 70, 77 °F |
ASTM No. 18C |
Cat No. 10018C-C |
Application Say Vis & Reid Vapor |
Range 34 to 42 °C |
Div 0.1° |
Length 275mm |
Immersion total |
ASTM specified test points 38, 41 °C |
ASTM No. 18F |
Cat No. 10018F-C |
Application Say Vis & Reid Vapor |
Range 94 to 108 °F |
Div 0.2° |
Length 275mm |
Immersion total |
ASTM specified test points 100, 107 °F |
ASTM No. 19C |
Cat No. 10019C-C |
Application Viscosity Saybolt |
Range 49 to 57 °C |
Div 0.1° |
Length 275mm |
Immersion total |
ASTM specified test points 50, 54 °C |
ASTM No. 19F |
Cat No. 10019F-C |
Application Viscosity Saybolt |
Range 120 to 134 °F |
Div 0.2° |
Length 275mm |
Immersion total |
ASTM specified test points 122, 130 °F |
ASTM No. 20C |
Cat No. 10020C-C |
Application Viscosity Saybolt |
Range 57 to 65 °C |
Div 0.1° |
Length 275mm |
Immersion total |
ASTM specified test points 60, 64 °C |
ASTM No. 20F |
Cat No. 10020F-C |
Application Viscosity Saybolt |
Range 134 to 148 °F |
Div 0.2° |
Length 275mm |
Immersion total |
ASTM specified test points 140, 147 °F |
ASTM No. 21C |
Cat No. 10021C-C |
Application Viscosity Saybolt |
Range 79 to 87 °C |
Div 0.1° |
Length 275mm |
Immersion total |
ASTM specified test points 82, 86 °C |
ASTM No. 21F |
Cat No. 10021F-C |
Application Viscosity Saybolt |
Range 174 to 188 °F |
Div 0.2° |
Length 275mm |
Immersion total |
ASTM specified test points 180, 187 °F |
ASTM No. 22C |
Cat No. 10022C-C |
Application Say Vis &anp; Oxy Stab. |
Range 95 to 103 °C |
Div 0.1° |
Length 275mm |
Immersion total |
ASTM specified test points 99, 102 °C |
ASTM No. 22F |
Cat No. 10022F-C |
Application Say Vis & Oxy Stab. |
Range 204 to 218 °F |
Div 0.2° |
Length 275mm |
Immersion total |
ASTM specified test points 210, 212 °F |
ASTM No. 23C |
Cat No. 10023C-C |
Application Viscosity Engler |
Range 18 to 28 °C |
Div 0.2° |
Length 212mm |
Immersion 90mm |
ASTM specified test points 20, 25 °C |
ASTM No. 24C |
Cat No. 10024C-C |
Application Viscosity Engler |
Range 39 to 54 °C |
Div 0.2° |
Length 237mm |
Immersion 90mm |
ASTM specified test points 40, 50 °C |
ASTM Thermometers without calibration
ASTM No. | Cat No. | Application | Range | Div | Length | Immersion |
---|---|---|---|---|---|---|
ASTM No. 12C |
Cat No. 10012C |
Application Gravity (Density) |
Range -20 to 102 °C |
Div 0.2° |
Length 420mm |
Immersion total |
ASTM No. 12F |
Cat No. 10012F |
Application Gravity (Density) |
Range -5 to 215 °F |
Div 0.5° |
Length 420mm |
Immersion total |
ASTM No. 13C |
Cat No. 10013C |
Application Loss on Heat |
Range 155 to 170 °C |
Div 0.5° |
Length 155mm |
Immersion total |
ASTM No. 14C |
Cat No. 10014C |
Application Paraffin Wax Melt Point |
Range 38 to 82 °C |
Div 0.1° |
Length 375mm |
Immersion 79mm |
ASTM No. 14F |
Cat No. 10014F |
Application Paraffin Wax Melt Point |
Range 100 to 180 °F |
Div 0.2° |
Length 375mm |
Immersion 79mm |
ASTM No. 15C |
Cat No. 10015C |
Application Softening Point, Low |
Range -2 to 80 °C |
Div 0.2° |
Length 397mm |
Immersion total |
ASTM No. 15F |
Cat No. 10015F |
Application Softening Point, Low |
Range 30 to 180 °F |
Div 0.5° |
Length 397mm |
Immersion total |
ASTM No. 16C |
Cat No. 10016C |
Application Softening Point, High |
Range 30 to 200 °C |
Div 0.5° |
Length 397mm |
Immersion total |
ASTM No. 16F |
Cat No. 10016F |
Application Softening Point, High |
Range 85 to 392 °F |
Div 1° |
Length 397mm |
Immersion total |
ASTM No. 17C |
Cat No. 10017C |
Application Viscosity Saybolt |
Range 19 to 27 °C |
Div 0.1° |
Length 275mm |
Immersion total |
ASTM No. 17F |
Cat No. 10017F |
Application Viscosity Saybolt |
Range 66 to 80 °F |
Div 0.2° |
Length 275mm |
Immersion total |
ASTM No. 18C |
Cat No. 10018C |
Application Say Vis & Reid Vapor |
Range 34 to 42 °C |
Div 0.1° |
Length 275mm |
Immersion total |
ASTM No. 18F |
Cat No. 10018F |
Application Say Vis & Reid Vapor |
Range 94 to 108 °F |
Div 0.2° |
Length 275mm |
Immersion total |
ASTM No. 19C |
Cat No. 10019C |
Application Viscosity Saybolt |
Range 49 to 57 °C |
Div 0.1° |
Length 275mm |
Immersion total |
ASTM No. 19F |
Cat No. 10019F |
Application Viscosity Saybolt |
Range 120 to 134 °F |
Div 0.2° |
Length 275mm |
Immersion total |
ASTM No. 20C |
Cat No. 10020C |
Application Viscosity Saybolt |
Range 57 to 65 °C |
Div 0.1° |
Length 275mm |
Immersion total |
ASTM No. 20F |
Cat No. 10020F |
Application Viscosity Saybolt |
Range 134 to 148 °F |
Div 0.2° |
Length 275mm |
Immersion total |
ASTM No. 21C |
Cat No. 10021C |
Application Viscosity Saybolt |
Range 79 to 87 °C |
Div 0.1° |
Length 275mm |
Immersion total |
ASTM No. 21F |
Cat No. 10021F |
Application Viscosity Saybolt |
Range 174 to 188 °F |
Div 0.2° |
Length 275mm |
Immersion total |
ASTM No. 22C |
Cat No. 10022C |
Application Say Vis &anp; Oxy Stab. |
Range 95 to 103 °C |
Div 0.1° |
Length 275mm |
Immersion total |
ASTM No. 22F |
Cat No. 10022F |
Application Say Vis & Oxy Stab. |
Range 204 to 218 °F |
Div 0.2° |
Length 275mm |
Immersion total |
ASTM No. 23C |
Cat No. 10023C |
Application Viscosity Engler |
Range 18 to 28 °C |
Div 0.2° |
Length 212mm |
Immersion 90mm |
ASTM No. 24C |
Cat No. 10024C |
Application Viscosity Engler |
Range 39 to 54 °C |
Div 0.2° |
Length 237mm |
Immersion 90mm |
WARNING: Mercury is considered a hazardous material that can cause central nervous system, kidney and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury containing products. See the product Material Safety Data Sheet (MSDS) for details. User should be aware that selling mercury and mercury containing products into your state may be prohibited by state law.