Tape Calibration

Calibrated Tapes are Working Tapes used for tank gauging. Calibrated in accordance with API Chapter 3 Section 1A specifications.

To order: Add prefix from the below to the catalog number. Example CN1293SMEF590.903

 

Catalog No. Tape Length Description
720.001 25′ NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 8, 15, 20, 25′
720.002 33′ NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 8, 15, 30, 33′
720.003 50′ NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 15, 30, 45, 50′
720.004 66′ NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 15, 30, 45, 60, 66′
720.005 75′ NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 15, 30, 45, 60, 75′
720.006 100′ NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 15, 30, 45, 60, 75, 90, 100′
720.501 8 m NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 2, 4, 6, 8 m
720.502 10 m NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 2, 6, 8, 10 m
720.503 15 m NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 5, 8, 10, 15 m
720.504 20 m NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 5, 10, 15, 20 m
720.505 23 m NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 5, 10, 15, 20, 23 m
720.506 30 m NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 5, 10, 15, 20, 25, 30 m
720.901 25′ / 8 m NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 8, 15, 20, 25′ & 2, 4, 6, 8 m
720.902 33′ / 10 m NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 8, 15, 30, 33′ & 2, 6, 8, 10 m
720.903 50′ / 15 m NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 15, 30, 45, 50′ & 5, 8, 10, 15 m
720.904 66′ / 20 m NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 15, 30, 45, 60, 66′ & 5, 10, 15, 20 m
720.905 75′ / 23 m NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 15, 30, 45, 60, 75′ & 5, 10, 15, 20, 23 m
720.906 100′ / 30 m NIST traceable linearity calibration in accordance with API Chapter 3 specifications at test points 15, 30, 45, 60, 75, 90, 100′ & 5, 10, 15, 20, 25, 30 m