Accredited calibration services: 

Temperature calibration

From -196oC to 1000oC   ASTM thermometers, digital thermometers, PRTs, thermocouples, thermistors

Hydrometer calibration

Specific Gravity hydrometers. API hydrometers, Baume hydrometers,
Kg/M3 (density) hydrometers, Brix hydrometers, Proof hydrometers

Mass (weight) calibration

ASTM Class 1 and OIML E-2 and lesser specification stainless steel and brass laboratory weights.  New calibrated weights and re-calibration of weights you currently have.

Humidity calibration

Thermo-hygrometers, chart recorders, humidity sensors, data-loggers

Volumetric calibration

Burets, pipets, volumetric flasks, graduated cylinders, volumetric glassware

Verification services

 Testing and certification that an instrument complies with specified accuracy requirements...

Recalibration

Our A2LA Scope

About ICL-Company info

Forms & downloads

FAQs and help topics

Sample reports

Request catalog

Multi-Function RVP Sampling System

 

 

 

 

 

 

 

ALL-IN-ONE SAMPLER FOR RVP SAMPLING AND TRANSFER OF GASOLINE

            FEATURES

  • Adjustable Neck opening to ¾” (19mm)

  • Running Sampler (Composite Sampling)

  • Spot Sampler (top, middle, bottom)

  • All level sampler (Representative Sampling)

  • Uses the same technology as the EPA approved RVP nozzle extension method for sampling of gas stations.

  • Maintains vapor pressure integrity during transfer of sample

  • Can be used in open or closed tanks with MMC or TS Hermetic VCV's

  • Fits inside the Multi-Function Sampling System for Closed and Restricted Sampling System

  • Volume Capacity equals 75 to 80 percent of 1 quart size container

  • Suitable for RFG Sampling

  • Modular and non-sparking brass construction

Background Information

Reid Vapor Pressure (RVP) testing of gasoline has been designated by the

U.S. EPA as well as State Agencies as the test method to determine the volatility of gasoline.  During the spring and summer months, the permissible amount of Text Box: RVP
Multi-Function
sampler

RVP is normally lower than during the winter months in order to reduce the volatility of organic compounds (VOC) escaping into the atmosphere.                        

General Description

The Multi-Function Sampling System is designed to obtain gasoline samples from storage tanks ashore or on marine vessels.  It enables one to transfer from sampler into suitable sampling container without losing vapor pressure.  It consists of a specially designed spring loaded bottom valve and an RVP trip funnel designed to fit the RVP Sampler bottom.  This combination allows the transfer of gasoline without losing vapor pressure during the transfer process.

Description of Operation

The operator can choose the type of sampler needed by selecting one of the various tops included in the sampling kit. For example, for running sampling, you would choose the adjustable top.  For a zone sample, choose the zone bottom.

The RVP trip funnel is designed to open the spring-loaded bottom of the RVP sampler and decant the liquid sample through an extension nozzle, which extends into the bottom of a sample container, and enables it to be filled from the bottom.

Gauging Bag included FREE OF Charge!!

ICL Catalog Number: GB-2

ICL Catalog Number: Description

P300B-RVP

Multi-Function RVP Sampling System

Back to Petroleum Sampler Main Page

    

   ICL's main page             Contact us