Accredited calibration services: 

Temperature calibration

From -196oC to 1000oC   ASTM thermometers, digital thermometers, PRTs, thermocouples, thermistors

Hydrometer calibration

Specific Gravity hydrometers. API hydrometers, Baume hydrometers,
Kg/M3 (density) hydrometers, Brix hydrometers, Proof hydrometers

Mass (weight) calibration

ASTM Class 1 and OIML E-2 and lesser specification stainless steel and brass laboratory weights.  New calibrated weights and re-calibration of weights you currently have.

Humidity calibration

Thermo-hygrometers, chart recorders, humidity sensors, data-loggers

Volumetric calibration

Burets, pipets, volumetric flasks, graduated cylinders, volumetric glassware

Verification services

 Testing and certification that an instrument complies with specified accuracy requirements...

Recalibration

Our A2LA Scope

About ICL-Company info

Forms & downloads

FAQs and help topics

Sample reports

Request catalog

 

CANNON-UBBELOHDE FOUR-BULB

SHEAR DILUTION VISCOMETERS

Supplied with Cannon® Instrument Company’s ISO/IEC 17025 Report of Calibration  

Text Box: Specifications
For Five-fold Dilution type

Size	Approx.Constant,cSt/s	*RangecSt	Shear Rate at wallreciprocalseconds
25	0.002	0.4 to 2	82/1650
50	0.004	0.8 to 4	45/900
75	0.008	1.6 to 8	24/480
100	0.015	3 to 15	15/300
150	0.035	7 to 35	8/160

CANNON-UBBELOHDE FOUR-BULB SHEAR DILUTION VISCOMETERS

FIVE-FOLD DILUTION TYPE

For measurement of intrinsic viscosities extrapolated to zero shear rates.  Provide five-fold range of shear rates. Design gives extra mechanical strength.  Negligible kinetic energy correction.

Provided with Cannon's ISO/IEC 17025 certificate of calibration and instruction sheet.   

    Minimum sample volume 20 mL. Require liquid bath depth of 280 mm (11 inches). 

    Holder is not supplied.  Refer to catalog # 9726-M70, M73, and M76

 TEN-FOLD DILUTION TYPEText Box: Specifications
For Ten-fold Dilution type

Size	Approx.Constant,cSt/s	*RangecSt	Shear Rate at wallreciprocalseconds
25	0.002	0.4 to 2	82/3300
50	0.004	0.8 to 4	45/1800
75	0.008	1.6 to 8	24/960
100	0.015	3 to 15	15/600
150	0.035	7 to 35	8/320

Similar to 9723-M50 series, but provide ten-fold range of shear rates.

Provided with Cannon's ISO/IEC 17025 certificate of calibration and instruction sheet.   

    Minimum sample volume 20 mL. Require liquid bath depth of 430 mm (17 inches).Text Box: Size	     Catalog #

25	9723-R50
50	9723-R53
75	9723-R56
100	9723-R59
150	9723-R62

 ■    Holder is not supplied.  Refer to catalog # 9726-M70, M73, and M76

 

 

Need viscosity standards for checking your viscometers?  We carry Cannon® viscosity standards!

Recalibration form and address label to send in your viscometer for calibration

    

   ICL's main page             Contact us