Accredited
calibration services:

From -196oC
to 1000oC ASTM thermometers, digital thermometers, PRTs,
thermocouples, thermistors

Specific Gravity
hydrometers. API hydrometers, Baume hydrometers,
Kg/M3 (density) hydrometers, Brix hydrometers, Proof hydrometers

ASTM Class 1 and
OIML E-2 and lesser specification stainless steel and brass laboratory weights.
New calibrated weights and re-calibration of weights you currently have.

Thermo-hygrometers,
chart recorders, humidity sensors, data-loggers

Burets, pipets,
volumetric flasks, graduated cylinders, volumetric glassware

Testing and
certification that an instrument complies with specified accuracy
requirements...







| |
MMC International
Portable
Electronic Gauging Tapes for Petroleum and Chemical Tanks
CLOSED (GAS-TIGHT)
|

|
MMC is
the world's leading manufacturer of portable instruments for measuring
ullage, oil-water interface, temperature, and bottom dryness in shipboard
and land-based petroleum and chemical tank systems. All MMC systems
are manufactured in the United States and are certified as intrinsically
safe by Factory
Mutual, BASEEFA, CSA and SAA.
The Portable Closed Flexi-Dip measuring tape is a battery-operated electronic unit that
is totally gas-tight. When installed in a vapor-control valve mounted on a storage (cargo)
tank, it forms a tightly sealed system that prevents toxic vapors from escaping and
creates a closed gauging system for that tank. The tape is marked in metric or english
units and is anti-static coated (as is the sensor). In addition, the tape is color marked to
make tape direction and motion easily seen and to ensure full rewind position. A coiled
grounding cable with large alligator clip is standard. This closed system is recognized by
many worldwide regulatory bodies as equivalent to a fixed gauging system as long as
the tape remains in the valve from the beginning until the end of loading or discharging of the tank.
|
|

ISO/IEC
17025 REPORT OF CALIBRATION INCLUDED! |
SPECIFICATIONS
Accuracy
-
of Tape Reading: Fluid level +/- 1/8 inch (3mm), +/- 0.01% of F.S. tape
LGT (F.S. = Full Scale).
-
of Temperature Display: +/- 0.5° F (+/- 0.3° C), +/- 1 digit error.
Ambient
Temperature Limits:
-20° F (-7° C) to 120° F (49° C).
Product Temperature Limits: -40° F (-40° C) to 180° F (82° C).
Battery: 9-Volt Eveready # 522 or Mallory MN1604.
Tape Lengths: 50 ft. (15m), 75 ft. (25m), 100 ft. (30M).
Typical Weights: 14 lbs. (6.4 KG).
Pressure Limits: 3 psi working, 7.5 psi maximum.
Approvals: Intrinsically safe--FM, BASEEFA, CSA, SAA, NKK (Japan).
|
| ICL
Catalog Number: |
Tape
Length |
Description |
|
2401TC050FFM-STD |
50' |
Closed/Gas Tight Tri-Mode |
|
2401TC15MFFM-STD |
15 Meter |
Closed/Gas Tight Tri-Mode |
|
2401TC100FFM-STD |
100' |
Closed/Gas Tight Tri-Mode |
|
2401TC30MFFM-STD |
30 Meter |
Closed/Gas Tight Tri-Mode |
Optional Calibration
|
Tape Calibration-MMC |
NIST Traceable Certificate of
Linearity Calibration in accordance with API Chapter 3. |
Replacement Barrels
| B2562-257 |
Replacement barrel – (MB, MMB type vapor valves) |
|
A2562-309 |
Replacement barrel – (MMC “A” C50, F50 type vapor valves) |
|
B2562-267 |
Replacement barrel – (Hermetic C2.SS vapor valves) |
|
B2562-262 |
Replacement barrel – (Hermetic A2.SS vapor valves) |
More MMC
models
MMC Repair and Recalibration
|